Sign In | Join Free | My enlightcorp.com
China Wuxi Consensic Electronic Technology Co., Ltd. logo
Wuxi Consensic Electronic Technology Co., Ltd.
Wuxi Consensic Electronic Technology Co., Ltd.
Verified Supplier

2 Years

Home > Medical Flow Sensors >

High Accuracy 1.5%F. S Accuracy Analog Output 1 To 5V Medical Flow Sensors

Wuxi Consensic Electronic Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

High Accuracy 1.5%F. S Accuracy Analog Output 1 To 5V Medical Flow Sensors

Brand Name : Consensic

Model Number : CAFS6000

Certification : PTC22072602101C-CN01

Place of Origin : WUXI

MOQ : Please contact us for details

Price : Offline contact or face-to-face discussion can be negotiated

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram/Alipay/business-to-business

Supply Ability : 1000

Delivery Time : 3-7 work days

Maximum voltage output : 4.96 ~5.02V linear

Maximum operating temperature range : -15°C to + 70°C

response time : 9~500ms customizable

Calibration conditions : 0℃, 1 standard atmosphere

accuracy : 2%FS

Flow range : 0~10000sccm Customizable specifications

Contact Now

Fit & Install

1. Ensure that the sensor is not damaged and the wiring is complete;

2. When installing and connecting, the airflow direction is consistent with the sensor airflow indication direction, and the sensor lead line should be correctly connected according to the definition;

3. After confirming the correct connection, then connect the power supply to start work;

4. The sensor is connected to the power supply as far as possible after preheating for 2 minutes before use, better accuracy.

Performance Metrics

Test conditions: Vin = 12±0.1VDC, Ta=25°C. Relative humidity: 40% <relative humidity <60%.

Maximum operating temperature range-15°C to + 70°C

specifications

High Accuracy 1.5%F. S Accuracy Analog Output 1 To 5V Medical Flow Sensors

least value normal value crest value unit remarks
Flow range 0

10000 sccm Customizable specifications
service voltage 8-24V V customizable
current 50 mA
Maximum voltage output 4.96 5 5.02 V linear
Zero point voltage output 0.98 1 1.02 V linear
accuracy 1.5 2 %FS
repetitiveness ±0.3 %
resolution ratio 0.1 % gamut
withstand voltage 0.3 0.5 MPa customizable
response time 9 65 500 ms customizable
zero drift 0.2 %Year gamut
Calibration conditions 0℃, 1 standard atmosphere
The overall material Silicon carbide, epoxy resin, PPS, and silicon shall serve as the sealing material

Product Tags:

5v medical flow sensors

      

high accuracy medical flow sensors

      

5V medical flow sensors

      
Quality High Accuracy 1.5%F. S Accuracy Analog Output 1 To 5V Medical Flow Sensors for sale

High Accuracy 1.5%F. S Accuracy Analog Output 1 To 5V Medical Flow Sensors Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Wuxi Consensic Electronic Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)